Add to Cart
Hoist Conductor Rails , Bus Bar Electrification System For Overhead Crane
Quick Details
Model | Pole No. | Cross section | Max. current | Leakage-distance | Max. voltage | Resistance | Dimensions (H * W) | Weight |
HFP56-3-10/50 | 3 | 10 | 50 | 45 | 600 | 1.656 | 73*56 | 1.95 |
HFP56-3-15/80 | 3 | 15 | 80 | 45 | 600 | 1.137 | 73*56 | 2.13 |
HFP56-3-20/100 | 3 | 20 | 100 | 45 | 600 | 1.011 | 73*56 | 2.24 |
HFP56-3-25/120 | 3 | 25 | 120 | 45 | 600 | 0.713 | 73*56 | 2.37 |
HFP56-3-35/140 | 3 | 35 | 140 | 45 | 600 | 0.522 | 73*56 | 2.63 |
HFP56-3-50/170 | 3 | 50 | 170 | 45 | 600 | 0.337 | 73*56 |
3.02 |
Detailed Product Description
These systems feature multiple conductors, typically copper strips, in an insulated enclosure. The current collector tracks are inside the enclosure, with the joining electric cable connected via an opening (slot) in the bottom of the enclosure. The bottom opening can be sealed with a neoprene sealing strip to keep debris and fumes out. The current collector is self-guided in these systems and only needs to be towed with a towing arm. Multiple copper conductors in an enclosure (aluminium or PVC housing) is available in 3 to 16 conductors and amperage capacities from 30 to 240.
Design features
Compact arrangement, corrosion resistance and simple assembly are its essential features.
Couplings
Through PVC joint caps.
Feed Sets
Line feeds or end feeds.
End caps
The open ends of the powerail are closed by end caps for HFP.
Hangers
Standard brackets for powerail attachment to crane girders are available.
Powerail with sliding and fixpoint hangers.
Standard distance between suspension points for indoor and outdoor installations:1200mm.
Hoist Conductor Rails
Technical Parameters Bus Bar Electrification System For Overhead Crane
HFP Series Multiple-Poles Conductor Rail System |
|||
Max. voltage |
600v |
Bending strength |
75N/mm²±10% |
Dielectric strength |
30-40kv/mm |
Tensile strength |
40N/mm²±10% |
Special resistance |
5×1015 Ohm×cm |
Leakage resistance |
CTI600-2,7 |
Surface resistance |
1013 Ohm×cm |
Design and Manufacturing Standard |
GB7251.2-2006 |
Distance between each suspension bracket (m) |
1.2 |
Rail length per piece (m) |
4 |
Flame retardant |
Class B1-no flaming particles, self-extinguishing |
||
Permissible Ambient temperature |
Standard insulation -30℃- +70℃|High temperature insulation -20℃- +115℃|Low temperature insulation -40℃- +80℃ |